Product Detail
18/30 kV or 19/33 kV XLPE Insulated, Radial and Longitudinally Sealed Single Core Cables with Aluminum Conductor
Code NA2XS(FL)2Y, AL/XLPE/CWS/LW/PE Standards IEC 60502-2, VDE 0276-620, BS 7870 - 4.10
|
Application Characterized with low
dielectric loss. Used in energy networks where load may change suddenly. Laid
in residential or industrial areas, and underground in ducts. In case water
sneaks into cable due to any mechanical damage, swellable tape prevents penetration
of water inside the cable. Construction 1. Stranded aluminum conductor 2. Inner
semi-conductive layer 3. XLPE
insulation 4. Outer
semi-conductive layer 5.
Semi-conductive swelling tape 6. Copper
screen 7. Swellable
tape 8. PE coated aluminum foil 9. PE outer jacket |
||||||||||||||
Technical
Data |
|
|
|||||||||||||
Max. operating temperature |
: |
90 oC |
|||||||||||||
Max. short circuit temperature |
: |
250 oC (Max. 5 sec.) |
|||||||||||||
Rated voltage |
: |
18/30 kV |
|||||||||||||
|
|
19/33 kV |
|||||||||||||
Min. bending radius |
: |
15 x D |
|||||||||||||
(D: Cable outer diameter) |
|||||||||||||||
DIMENSIONS AND WEIGHTS |
ELECTRICAL PROPERTIES |
||||||||||||||
Nominal |
Overall |
Net |
Delivery Length |
DC
Conductor |
DC
Conductor |
Operation
Inductance |
Operation Capacitance |
Current
Carrying Capacity (A) |
|||||||
Cross |
Diameter |
Weight |
Resistance
at |
Resistance
at |
|||||||||||
Section |
(approx.) |
(approx.) |
20 0C
Max |
90 0C
Max |
|||||||||||
|
|
|
|
|
|
|
|
|
In
ground at 20oC |
In
air at 30oC |
|||||
mm2 |
mm |
kg/km |
m |
Ohm/km |
Ohm/km |
mH/km |
mH/km |
µF/km |
|||||||
|
|
|
|
|
|
*** |
*** |
|
*** |
*** |
*** |
*** |
|||
1x35/16 |
36.5 |
950 |
1000 |
0.868 |
1.1110 |
0.688 |
0.474 |
0.123 |
- |
- |
- |
- |
|||
1x50/16 |
37.5 |
1100 |
1000 |
0.641 |
0.8205 |
0.662 |
0.453 |
0.135 |
196 |
175 |
217 |
187 |
|||
1x70/16 |
39.5 |
1250 |
1000 |
0.443 |
0.5670 |
0.631 |
0.429 |
0.151 |
238 |
214 |
270 |
232 |
|||
1x95/16 |
41.0 |
1350 |
1000 |
0.320 |
0.4096 |
0.607 |
0.410 |
0.166 |
284 |
256 |
328 |
281 |
|||
1x120/16 |
43.0 |
1500 |
1000 |
0.253 |
0.3238 |
0.588 |
0.397 |
0.180 |
322 |
290 |
378 |
323 |
|||
1x150/25 |
44.5 |
1750 |
1000 |
0.206 |
0.2637 |
0.570 |
0.383 |
0.194 |
355 |
324 |
425 |
365 |
|||
1x185/25 |
46.5 |
1900 |
1000 |
0.164 |
0.2099 |
0.554 |
0.372 |
0.208 |
400 |
366 |
485 |
418 |
|||
1x240/25 |
49.5 |
2150 |
1000 |
0.125 |
0.1600 |
0.534 |
0.359 |
0.229 |
461 |
426 |
572 |
494 |
|||
1x300/35 |
51.5 |
2450 |
1000 |
0.100 |
0.1280 |
0.517 |
0.347 |
0.248 |
516 |
478 |
649 |
564 |
|||
1x400/35 |
55.0 |
2950 |
1000 |
0.0778 |
0.1009 |
0.495 |
0.334 |
0.276 |
592 |
545 |
737 |
654 |
|||
1x500/35 |
58.0 |
3350 |
1000 |
0.0605 |
0.0774 |
0.479 |
0.324 |
0.301 |
638 |
614 |
835 |
747 |
|||
1x630/35 |
62.0 |
3850 |
1000 |
0.0469 |
0.0600 |
0.463 |
0.314 |
0.330 |
728 |
690 |
950 |
851 |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
NOTE : Current carrying
capacities are valid under the following conditions.
In ground :
200C; buried in 70 cm depth; soil thermal resistivity 1 K.m/W; load
factor 0.7
In Air :
300C; load factor 1.0
*** :
Flat formation; clearance between cables in air = 1 x cable outer diameter; in
ground = 7cm
*** :
Trefoil formation
Number of System : 1
Resources
Get a copy of brochure on Al Conductor, XLPE Insulated, R&L Sealed, Single Core MV Cables (18/30 kV).